Close

1. Identity statement
Reference TypeConference Paper (Conference Proceedings)
Sitemtc-m21b.sid.inpe.br
Holder Codeisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identifier8JMKD3MGP5W34M/3FA462C
Repositorysid.inpe.br/mtc-m21b/2013/11.26.17.01.40
Last Update2018:08.27.12.47.54 (UTC) marcelo.pazos@inpe.br
Metadata Repositorysid.inpe.br/mtc-m21b/2013/11.26.17.01.41
Metadata Last Update2021:02.11.18.29.53 (UTC) administrator
ISBN9781624102158
Labelscopus 2013-11
Citation KeyRiehlCach:2013:PuHePi
TitlePulsating heat pipes used for thermal control of electronics on surveillance systems
Year2013
Access Date2024, Apr. 26
Secondary TypePRE CI
Number of Files1
Size1525 KiB
2. Context
Author1 Riehl, Roger Ribeiro
2 Cachuté, Liomar de Oliveira
Group1 DMC-ETE-INPE-MCTI-GOV-BR
2 CMC-ETES-SPG-INPE-MCTI-GOV-BR
Affiliation1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Instituto Nacional de Pesquisas Espaciais (INPE)
Author e-Mail Address1 rriehl@dem.inpe.br
e-Mail Addressmarcelo.pazos@inpe.br
Conference NameInternational Conference on Environmental Systems, 43 (ICES).
Conference LocationVail
Date14 -18 July 2013
Publisher CityVail, CO
OrganizationParagon
History (UTC)2014-01-09 13:37:32 :: administrator -> marcelo.pazos@sid.inpe.br :: 2013
2014-01-10 11:06:09 :: marcelo.pazos@sid.inpe.br -> administrator :: 2013
2018-06-04 03:14:13 :: administrator -> marcelo.pazos@inpe.br :: 2013
2018-08-27 12:47:55 :: marcelo.pazos@inpe.br -> administrator :: 2013
2021-02-11 18:29:53 :: administrator -> marcelo.pazos@inpe.br :: 2013
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
Version Typepublisher
KeywordsActive thermal control systems
Design and application
Electronic component
Heat pipe technology
Loop pulsating heat pipes
Pulsating heat pipe
Surveillance systems
Thermal control devices
Heat pipes
Liquids
Temperature control
Security systems
AbstractSurveillance systems have proven to be important applications for high performance thermal control devices, especially the passive ones using heat pipe technology. With the growing need for heat dissipation presented by this type of system, usually hybrid solutions are designed, which include both liquid cooling and passive two-phase thermal control. This last one is usually applied when the heat source is located far from the heat sink and the use of liquid cooling or any other active thermal control system is not possible due to the lack of available space for integration. Since most of the surveillance systems being designed today require thermal control devices that operate under adverse orientation, some restrictions apply. Therefore, the technology that is currently used and disseminated for aerospace missions can find many other applications on surveillance systems for defense purposes. With severe restrictions regarding available space for integration of common thermal control devices, the design and application of pulsating heat pipes become the most indicated solution for the present investigation. Previous investigations have demonstrated that pulsating heat pipes configured as an open loop can operate on adverse conditions, promoting the heat transport from the source to the sink with good reliability. Based on this fact, this investigation is focused on presenting the thermal management of electronic components of a surveillance system being done by pulsating heat pipes configured as open loops. Despite the relatively high temperature difference between the heat source and sink, the open loop pulsating heat pipe is able to transport the rejected heat from the electronic components to a remote heat dissipation area, while keeping their temperatures within the required range established by the project. The operation of the pulsating heat pipes have proven to be stable and reliable, meeting the project's expectations for thermal control.
AreaETES
Arrangement 1urlib.net > BDMCI > Fonds > Produção pgr ATUAIS > CMC > Pulsating heat pipes...
Arrangement 2urlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDMC > Pulsating heat pipes...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
data URLhttp://urlib.net/ibi/8JMKD3MGP5W34M/3FA462C
zipped data URLhttp://urlib.net/zip/8JMKD3MGP5W34M/3FA462C
Languageen
User Groupadministrator
marcelo.pazos@inpe.br
Reader Groupadministrator
marcelo.pazos@inpe.br
Visibilityshown
Update Permissionnot transferred
5. Allied materials
Mirror Repositoryiconet.com.br/banon/2006/11.26.21.31
Next Higher Units8JMKD3MGPCW/3F2UALS
8JMKD3MGPCW/446AF4B
Citing Item List
Host Collectionsid.inpe.br/mtc-m21b/2013/09.26.14.25.20
6. Notes
Empty Fieldsarchivingpolicy archivist booktitle callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi edition editor format issn lineage mark nextedition notes numberofvolumes orcid pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher readpermission resumeid rightsholder schedulinginformation secondarydate secondarykey secondarymark serieseditor session shorttitle sponsor subject targetfile tertiarymark tertiarytype type url volume
7. Description control
e-Mail (login)marcelo.pazos@inpe.br
update 


Close